Article successfully added.
CyFlow™ CD177 Alexa Fluor™ 647
Application: | Flow cytometry |
Format/Fluorochrome: | Alexa Fluor™ 647 |
Alternative Name: | HNA-2a, HNA2A, NB-1, NB1, PRV1 |
Antigen: | CD177 |
Emission Maximum: | 665 nm |
Target Species: | Human, Non-Human Primates |
Clonality: | monoclonal |
Isotype: | IgG1 |
Excitation Maximum: | 650 nm |
Laser: | Red |
Field of Interest: | Immunophenotyping |
Source Species: | Mouse |
Regulatory Status: | RUO |
Clone: | MEM-166 |
Order number: | AZ409280 |
For Research Use Only
Not for use in diagnostic or therapeutic procedures.
Quantity 100 tests Volume 0.4 mL Immunogen Human granulocytes Background... more
Product information "CyFlow™ CD177 Alexa Fluor™ 647"
Quantity | 100 tests |
Volume | 0.4 mL |
Immunogen | Human granulocytes |
Background Information | CD177 (NB1, HNA-2a and PRV-1 form) is a GPI-anchored glycoprotein present mainly on neutrophils. Its plasma membrane expression is increased during pregnancy and and inflammation or after G-CSF application. Ligand of CD177 has been identified as CD31 (PECAM-1). CD177 participates in neutrophil transmigration and seems to be also a pro-proliferative molecule. The antibodies against CD177 can be involved in neonatal alloimmune neutropenia (NAN). |
Usage | The reagent is designed for Flow Cytometry analysis of human blood cells. Recommended usage is 4·µl reagent·/ 100·µl of whole blood or 10^6 cells in a suspension. The content of a vial (0.4 ml) is sufficient for 100 tests. |
Storage Buffer | The reagent is provided in stabilizing phosphate buffered saline (PBS) solution, pH ≈7.4, containing 0.09% (w/v) sodium azide and 0.2% (w/v) BSA. |
Storage | Avoid prolonged exposure to light. Store in the dark at 2-8°C. Do not freeze. |
Stability | Do not use after expiration date stamped on vial label. |
Safety Data Sheet
Technical Data Sheet
Similar products
FITC
CyFlow™ CD1a FITC
Antigen: | CD1a |
Clone: | SK9 |
Application: | Flow cytometry |
Regulatory Status: | RUO |
Target Species: | Human | Quantity: | 100 tests |
PE
CyFlow™ CD1a PE
Antigen: | CD1a |
Clone: | SK9 |
Application: | Flow cytometry |
Regulatory Status: | RUO |
Target Species: | Human | Quantity: | 100 tests |
APC
CyFlow™ CD1a APC
Antigen: | CD1a |
Clone: | SK9 |
Application: | Flow cytometry |
Regulatory Status: | RUO |
Target Species: | Human | Quantity: | 100 tests |
Purified
CyFlow™ CD1a Purified
Antigen: | CD1a |
Clone: | SK9 |
Application: | Flow cytometry, Immunoprecipitation |
Regulatory Status: | RUO |
Target Species: | Human | Quantity: | 0.1 mg |
FITC
CyFlow™ CD1b FITC
Antigen: | CD1b |
Clone: | SN13 |
Application: | Flow cytometry |
Regulatory Status: | RUO |
Target Species: | Human | Quantity: | 100 tests |
Purified
CyFlow™ CD1b Purified
Antigen: | CD1b |
Clone: | SN13 |
Application: | Flow cytometry, Immunohistochemistry, Immunoprecipitation |
Regulatory Status: | RUO |
Target Species: | Human | Quantity: | 0.1 mg |
PE
CyFlow™ CD1c PE
Antigen: | CD1c |
Clone: | L161 |
Application: | Flow cytometry |
Regulatory Status: | RUO |
Target Species: | Human | Quantity: | 100 tests |
Purified
CyFlow™ CD1c Purified
Antigen: | CD1c |
Clone: | L161 |
Application: | Flow cytometry, Immunohistochemistry, Immunoprecipitation |
Regulatory Status: | RUO |
Target Species: | Human | Quantity: | 0.1 mg |